HTD-0029EP15
Type: EP15-012601
Technical requirements and electrical safety performance: Comply with GB/T 15290-2012 General Technical Specifications for Power Transformers and Filter Chokes for Electronic Equipment.
description
| Specification | HTD-0029EP15 | Version | Ver.1 | Date | 2026/5/13 | ||||||||
| Dimensions (in mm tolerance not specified is ±0.5). | |||||||||||||
![]() ![]() | |||||||||||||
| Main technical indicator | |||||||||||||
| Serial number | Parameter name | Parameter requirements | Test conditions / methods | ||||||||||
| 1 | Inductance | 4-5 | 1.2mH±10% | 100KHz, 1V | |||||||||
| 2 | TURN | N1:N2:N3:N4:N5 | 39.5:145:23:23:28 | 20KHz, 1V | |||||||||