Three Phase Four Wire Smart Energy Meter
Type: DTSD1311
This energy meter supports bidirectional active energy measurement and multiple instantaneous electrical parameter measurement. Its multi-tariff function can be effectively activated via internal settings, and power consumption can be tracked by means of load profile records. Apart from regular event logs, it records tampering events such as meter cover opening and magnetic interference. Near-infrared local communication is also available. Meter parameters can be freely configured through PC software with high flexibility.
description
This product is designed in compliance with IEC 62053-21 and IEC 62053-23. It meets the power quality requirements specified in EN 50160: 2007. The GPRS communication adopts the DLMS/COSEM protocol, while the local optical communication conforms to IEC62056-21 Mode E and DLMS/COSEM.
| Item | Sub-item | Parameter |
| Basic Parameters | Meter Type | Three-phase four-wire |
| Active Energy Accuracy | Class 1 (IEC 62053-21) | |
| Reactive Energy Accuracy | Class 2 (IEC 62053-23) | |
| Rated Voltage | 3×230V/400V Operating voltage: 0.8Un~1.2Un | |
| Rated Frequency | 50Hz Extended operating frequency range: ±2% | |
| Current Rating | 5(100)A | |
| Starting Current | 0.004Ib | |
| Pulse Constant | Active: 1000 imp/kWh Reactive: 1000 imp/kvarh | |
| Power Consumption | Current circuit: ≤0.5VA Voltage circuit: ≤2W / 5VA | |
| Temperature Range | Operating temperature: -30℃~55℃ Storage temperature: -40℃~+70℃ | |
| Energy Measurement | Active Energy Calculation | Active Energy(import) = import( |
| Instantaneous Values | Phase A/B/C Voltage (V) Phase A/B/C Current (A) Phase A/B/C Active Power (kW) Phase A/B/C Apparent Power (kVA) Phase A/B/C Reactive Power (kvar) Phase A/B/C Power Factor Grid Frequency (Hz) | |
| Communication | Local Communication 1 | Near infrared communication |
| Protocol 1 | IEC62056-21 Mode E | |
| TOU (Optional) | TOU Configuration | 2 sets of tariff schedules 4 tariff rates 12 daily schedules (max. 10 time intervals per day) 12 weekly schedules (7 daily schedules optional per week) 12 seasonal schedules (1 weekly schedule per season) 100 fixed & special holidays |
| RTC Clock Error | ≤0.5s/day at 23℃ | |
| Daylight Saving Time | DST automatic switching supported | |
| Clock Battery Life | Built-in backup battery: 3 years continuous operation under power outage | |
| Time Synchronization | MCU & local communication | |
| LED & Display | LED Indicators | 1 active pulse LED1 reactive pulse LED |
| LCD Screen | LCD area: over 8 cm² Minimum digit height: 8 mm | |
| Energy Display Format | Active energy: 8+0 Configurable: 8+0, 7+1, 6+2, 5+3 | |
| Instantaneous Value Format | Power: 0 decimal places Voltage: 1 decimal place Current: 2 decimal places Power factor: 1 integer + 2 decimals | |
| Display Modes | Auto display, key-triggered display, power-off wake-up display | |
| Display Content | Configurable, refer to list 5.2.2 | |
| Load Profile | Data Reading | Local or remote block reading |
| Load Profile 1 | Recording interval: 1~60 minutes (default 15 min) Capture items are configurable | |
| Billing & Maximum Demand | Demand Setting | Demand period: 1 / 5 / 10 / 15 / 30 / 60 minutes (selectable) |
| Monthly Billing Mode | Manual billing: trigger settlement by command Auto monthly billing: automatic settlement on scheduled date | |
| Billing Data Storage | Stores the latest 12 monthly billing records; items configurable | |
| Tampering & Event Log | Threshold Setting | Overvoltage, undervoltage, phase loss thresholds are configurable |
| Power Quality Events | Recorded data: Event time, serial number, event name | |
| Standard Events | Recorded data: Event time, serial number, event name | |
| Alarm Function | 1. Real-time status on Alarm Register 1&2 2. Event enable switch via Alarm Filter1&2 3. Latched records via Alarm Description1&2 | |
| Security | Password Management | 2 access levels:Admin & Reader |